¡á M-ÈÇÐ KS M 0129 ºÐ¼® ÈÇÐ ¿ë¾î (±¤ÇÐ ºÎºÐ)
1. 100´«±Ý Á¶Á¤ (Åõ°úÆÛ¼¾Æ®ÀÇ) (100 adjustment (of percentage transmission)) Åõ°ú ÆÛ¼¾Æ® ´«±ÝÀÇ Áö½Ã°è¿¡¼ °¡¸£Å°´Â °ÍÀ» 100ÀÇ ´«±Ý¿¡ ¸ÂÃß´Â Á¶ÀÛ. 2. 2Áß ÆÄÀå Ãø±¤ ¹æ½Ä (double wavelength spectrometry) ÃøÁ¤½Ã·á¿¡ ÆÄÀåÀÌ ´Ù¸¥ 2°³ÀÇ ´Ü»ö ºû»ìÀ» Åë°ú, ¹Ý»ç ¶Ç´Â Èí¼ö½ÃÄѼ ±×µéÀÇ ºû ¼¼±â¸¦ ÃøÁ¤ÇÏ´Â ¹æ½Ä. 3. °¡½Ã ½ºÆåÆ®·³ (visible spectrum) ÀüÀÚÆÄÀÇ ¹æ»ç Áß¿¡¼ ¾à 400nm¿¡¼ 800nm±îÁö ÆÄÀ念¿ªÀÇ ½ºÆåÆ®·³. 4. °£¼· (¿øÀÚ ½ºÆåÆ®·³ ºÐ¼®ÀÇ) (interference (in analytical atomic spectrometry)) °øÁ¸ÇÏ´Â ¹°ÁúÀÇ ¿µÇâ µîÀ¸·Î ºÐ¼®°ª¿¡ ¿ÀÂ÷°¡ »ý±â´Â °Í. ºÐ±¤°£¼·, ¹°¸® °£¼·, ÈÇÐ °£¼·, ÀÌ¿ÂÈ °£¼· µîÀÌ ÀÖ´Ù. 5. °£¼· ºÐ±¤¹ý (interferometry) °£¼·°è¿¡ ÀÇÇØ ¾ò¾îÁø ½ÅÈ£¸¦ ÇÁ¸®¿¡ÀÇ ¿ªº¯È¯À» ÇÏ¿© ½ºÆåÆ®·³À» ¾ò´Â ¹æ¹ý. 6. °£¼·¼º ¹Ý½ºÅ彺 ºÐ±¤¹ý (coherent anti-stokes Raman spectrometry, CARS) ·¹ÀÌÀú ¶ó¸¸ ºÐ±¤¿¡¼ ¹Ý½ºÅ彺¼±ÀÇ ¼¼±â¸¦ »ç¿ëÇÏ´Â ¹æ¹ý. 7. °íÀ¯ X¼± (characteristic X-ray) X¼± ½ºÆåÆ®·³ Áß ¿øÀÚÀÇ ³»ºÎ²®Áú ¿¡³ÊÁö¿¡ °íÀ¯ÇÑ X¼± . Ư¼º X¼±À̶ó°íµµ ÇÑ´Ù. 8. °íÁ¶ÈÆÄ ¹ß»ý (harmonic wave generation) ºñ¼±Çü ±¤ÇмÒÀÚ ÀÔ»çÇÑ ±¤ÀÌ º¸´Ù ªÀº ÆÄÀåÀ¸·Î ¹ß»ýµÇ´Â Çö»ó. ÆÄÀåÀÌ 1/2·Î µÇ´Â °æ¿ì¸¦ Á¦2°íÁ¶ÈÆÄ ¹ß»ý, 1/3·Î µÇ´Â °æ¿ì¸¦ Á¦3°íÁ¶ÈÆÄ ¹ß»ýÀ̶ó ÇÑ´Ù. 9. °ø¸í¼± (resonance line) ¿øÀÚ°¡ ¿ÜºÎ·ÎºÎÅÍ ±¤À» Èí¼öÇÏ¿© µé¶á ´ÙÀ½, ´Ù½Ã ¿ø·¡ »óÅ·ΠõÀÌÇÒ ¶§¿¡ ¹æ»çÇÏ´Â ¼±½ºÆåÆ®·³. 10. ±¤ºÐ¼® (photometric analysis) Àû¿Ü¼±º¸¿¡¼ Àڿܼ±ºÎ¿¡ °ÉÄ£ ÆÄÀ念¿ª¿¡¼ ¹æ»çÀÇ ¼¼±â¸¦ À°¾È, »çÁø¹ý, ±¤Àü¹ý µîÀÇ ¹æ¹ýÀ¸·Î ÃøÁ¤ÇÔÀ¸·Î½á ÇÏ´Â ÈÇкм®.
11. ±¤¿ ȸÀý (photothermal diffraction) ½Ã·á Áß¿¡¼ °°Àº ÆÄÀåÀÇ ·¹ÀÌÀú±¤À» ¹Ì¼ÒÇÑ °¢µµ·Î ±³Â÷½ÃÄѼ ±¤ Èí¼ö¿¡ ÀÇÇØ »ý±â´Â ¿ÀÇ ÁÖ±âÀû °£¼· ÁÙ¹«´Ì·Î ½ÃÇ豤À» ȸÀý½ÃÅ°´Â °Í. ´ë´ÜÈ÷ ¾àÇÑ Èí¼ö ÃøÁ¤¹ýÀÇ ÀÏÁ¾. 12. ±¤¿ÆíÇ⠺б¤¹ý (photothermal deflective spectrometry, PDS) µé¶ä±¤ÀÇ Èí¼ö¿¡ÀÇÇØ ¹ß»ýÇÑ ¿·Î ½Ã·á Ç¥¸éÀÇ ºÐÀ§±â ±âü°¡ °¡¿µÇ¾î ±¼Àý·üÀ» º¯È½ÃÅ°´Â °ÍÀ» Žħ±¤À¸·Î °ËÃâÇÏ´Â ºÐ±¤¹ý. ¹Ì¾àÀÇ Èí¼ö ÃøÁ¤¹ýÀÇ ÀÏÁ¾. 13. ±¤À½Ç⠺б¤¹ý (photoacoustic spcetrometry , PAS) ½Ã·á¿¡ Á¶»çµÈ ´Ü¼ÓÀûÀÎ µé¶ä±¤ÀÇ Èí¼ö¿¡ ÀÇÇØ ¹ß»ýÇÏ´Â °£ÇæÀû ¿ÆØâ¿¡ ±âÀÎÇÑ ¹ÐÁýµÈ Æĸ¦ À½ÇâÀûÀ¸·Î °ËÃâÇÏ´Â ºÐ±¤¹ý. 14. ±¤À½Çâ Çö¹Ì°æ ºÐ±¤¹ý (photoacoustic microscopy) ·¹ÀÌÀú±¤ µîÀ» °¡´Ã°Ô ÁÙÀÎ ±¤ºöÀ» ½Ã·á¸é¿¡ ´Ü¼ÓÀûÀ¸·Î Á¶»çÇÏ¿© ¹ß»ýÇÏ´Â ±¤À½Çâ ½ÅÈ£¸¦ °ËÃâÇÏ´Â ºÐ±¤¹ý. 15. ±¤Àü Ãø±¤¹ý (¹ß±¤ ºÐ±¤ ºÐ¼®ÀÇ) (photoelectric photometry (in emission spectrochemical analysis)) ºÐ±¤±â·Î ºÐ»êµÈ ½ºÆåÆ®·³¼±¿¡ ´ëÀÀÇÏ´Â À§Ä¡¿¡ ±¤Àü °ËÃâ±â¸¦ ¹èÄ¡ÇÏ°í µ¿½Ã¿¡ ´Ù¿ø¼Ò¸¦ ÃøÁ¤ÇÏ´Â ¹æ¹ý ¹× º¸ÅëÀÇ ºÐ±¤ ±¤µµ°è¿Í ¶È°°Àº ±¸Á¶·Î ½Å¼ÓÇÏ°Ô ÆÄÀåÁֻ縦 ÇÏ¿© ±¤ÀüÀûÀ¸·Î ÃøÁ¤ÇÏ´Â ¹æ¹ý. 16. ±¤ÀüÀÚ ºÐ±¤¹ý (photoelectron spectroscopy) Áø°ø Àڿܱ¤ ¶Ç´Â ÆÄÀåÀÌ ±ä X¼±À» ½Ã·á¿¡ Á¶»ç½ÃÄÑ ¾ò¾îÁö´Â ±¤ÀüÀÚ¸¦ °ËÃâÇÏ´Â ºÐ±¤¹ý. 17. ±¤ÇÐ ºÐÇÒ (optical resolution) °úÇÐ À̼ºÁúüÀÇ È¥ÇÕ¹° (¶ó¼¼¹Ìü)À» °¢°¢ÀÇ À̼ºÁúüº°·Î ºÐ¸®ÇÏ´Â °Í. 18. ±¤ÇÐ ¼øµµ (optical purity) 1½ÖÀÇ ´ë»ó¹°Ã¼·Î ÀÌ·ç¾îÁö´Â È¥ÇÕ¹° Áß¿¡ Á¸ÀçÇÏ´Â ÇÑÂÊ ±¤ÇÐ À̼ºÁúüÀÇ °úÀ×·®. {¤ÓR-S¤Ó/(R+S)} ¡¿ 100 À¸·Î Ç¥½ÃÇÑ´Ù. 19. ±¤ÇÐ ÇÊÅÍ (optical filter) ƯÁ¤ ÆÄÀ念¿ªÀÇ ºûÀ» Åë°ú½ÃÄѼ ´Ù¸¥ ÆÄÀå ¿µ¿ªÀÇ ºûÀ» Èí¼öÇÏ´Â ¹°Áú·Î ÀÌ·ç¾îÁö´Â ÃþÀ» »ç¿ëÇÏ¿© ƯÁ¤ ÆÄÀå ¿µ¿ªÀÇ ºûÀ» ³»±â À§ÇØ »ç¿ëÇÏ´Â ±¤ÇÐ ¼ÒÀÚ. 20. ±¤ÇÐ È°¼º (optical activity) (1)¹°ÁúÀÌ ¼±±¤¼±À» °®´Â °Í. (2)ºÐÀÚ Áß¿¡ ºñ´ëĪ ź¼Ò¿øÀÚ¸¦ °®´Â °Í. 21. ±¤ÇÐÀû ¿µÁ¡¹ý (optical null method) ÀÌÁߺû»ì ¹æ½ÄÀÇ ºÐ¼®±â±â¿¡¼ ½Ã·á ÃøÁ¤ ¼¼±âÀÇ ±¤·®°ú ±âÁØ ½Ã·á¸¦ ÃøÁ¤ÇÑ ¼¼±â°¡ °°¾ÆÁöµµ·Ï ±âÁØ ½Ã·á¿¡ ¼³Ä¡ÇÑ ±¤°¨¼â½Ã¸¦ ¿òÁ÷¿©¼ ±× º¯À§·ÎºÎÅÍ Åõ°úÀ²À» ±¸ÇÏ´Â ¹æ¹ý. 22. ±¤È¸Àü °¢µµ (angle of rotation) ±¤ÇÐ È°¼º¹°ÁúÀÌ Æí±¤¸éÀ» ȸÀü½ÃÅ°´Â Á¤µµ. °¢µµ·Î Ç¥½ÃÇÏ°í ¿ìȸÀüÀÎ °æ¿ì¸¦ +,ÁÂȸÀüÀÎ °æ¿ì¸¦ -·Î Ç¥½ÃÇÑ´Ù. 23. ±¤È¸Àü ºÐ»ê (optical rotatory dispersion, ORD) ±¤ÇÐ À̼ºÁúüÀÇ °¡½Ã ¤ýÀڿܼ± ¿µ¿ª¿¡¼ÀÇ ±¤È¸Àü °¢µµ°¡ ÆÄÀå¿¡ µû¶ó º¯ÈÇÏ´Â Çö»ó. ƯÈ÷ ÄÚÆ° È¿°ú¸¦ Çؼ®´ë»óÀ¸·Î ÇÑ´Ù. 24. ±Ô¼Ò-¸®Æ¬ ¹ÝµµÃ¼ °ËÃâ±â (Si (Li) semiconductor detector) ±Ô¼Ò Áß¿¡ ¸®Æ¬À» ¹Ì·® °¡ÇÏ¿© ¸¸µç Àý¿¬ÃþÀ» »ðÀÔÇÏ¿© P-I-NÁ¢ÇÕÇÑ ¼ÒÀÚ¸¦ »ç¿ëÇÏ°í , ÀÔ»ç X¼± ¿¡³ÊÁö¸¦ ºñ·ÊÇÏ´Â Àü·ùÆÞ½º¸¦ Ãâ·ÂÇÏ´Â °ËÃâ±â. ¿¡³ÊÁö ºÐ»ê ¹æ½Ä¿¡ »ç¿ëµÈ´Ù. 25. ±ÙÁ¢¼± (neighbouring line) ºÐ¼®¼±¿¡ ±ÙÁ¢ÇÏ´Â ¼±½ºÆåÆ®·³. 26. ±Û·Î ¹æÀü ¹ß±¤ ºÐ±¤ºÐ¼® (glow discharge atomic emission spectrochemical analysis) ±×¸²¤ý±Û·Î µîÀ» ±¤¿øÀ¸·Î ÇÑ ¹ß±¤ ºÐ±¤ºÐ¼®. 27. ±â¿ï±â ºñ¹ý (slope ratio method) M°ú A¿¡ ÀÇÇØ ÈÇÕ¹° MmAnÀ» »ý¼ºÇÒ ¶§ °úÀ×MÀÌ Á¸Àç ÇÏ¿¡¼ AÀÇ ³óµµ¸¦ º¯È½ÃÄÑ ¾ò¾îÁö´Â Èí±¤µµ¿Í A³óµµÀÇ °ü°èÁ÷¼±ÀÇ ±â¿ï±â ¹× °úÀ× AÀÇ Á¸Àç ÇÏ¿¡¼ MÀÇ ³óµµ¸¦ º¯È½ÃÄÑ ¾ò¾îÁö´Â Èí±¤µµ¿Í M ³óµµÀÇ °ü°è Á÷¼±ÀÇ ±â¿ï±â ºñ·ÎºÎÅÍ Á¶¼ººñ m°ú nÀ» ±¸ÇÏ´Â ¹æ¹ý. 28. ±âÁØ ±âü (Àû¿Ü¼± ±âü ºÐ¼®°èÀÇ) (reference gas (for infrared gas analyzer)) ½Ã·á ¼¿·Î Àû¿Ü¼± Èí¼ö¸¦ ÃøÁ¤ÇÏ´Â °æ¿ìÀÇ ´ë»óÀÌ µÇ´Â °ÍÀ¸·Î¼, Àû¿Ü¼±À» Èí¼öÇÏÁö ¾Ê´Â ±âü. 29. ±âÁØ ¿ë¾× (reference solution) ½Ã·á¿ë¾×ÀÇ »ö±òÀ̳ª Èí¼öÁ¤µµ¸¦ ºñ±³Çϱâ À§ÇÏ¿© »ç¿ëµÇ´Â Ç¥ÁØÀûÀÎ »ö±òÀ̳ª Èí¼ö¸¦ Ç¥½ÃÇÏ´Â ¿ë¾×. 30. ±âÁؼ¿ (Èí±¤±¤µµ ºÐ¼®¹ýÀÇ) (reference cell(in molecular absorption spectrometry)) ¼·Î Àß ÀÏÄ¡µÇ´Â 2°³ ÀÌ»óÀÇ ¼¿À» »ç¿ëÇÏ¿© Èí±¤µµ¸¦ »ç¿ëÇÒ ¶§, ¿ë¸Å ¶Ç´Â ±âÁØ¿ë¾×À» ³ÖÀº ÂÊÀÇ ¼¿. 31. ±âü¼¿ (gas absorption cell , gas cell) Èí±¤µµ¸¦ ÃøÁ¤Çϱâ À§ÇÏ¿© ±âü½Ã·á¸¦ ³Ö´Â ¿ë±â. 32. ³»ºÎ Ç¥ÁØ ¹°Áú. (internal standard substance) ³»ºÎ Ç¥Áعý¿¡¼ Ç¥ÁØÀ¸·Î »ç¿ëµÇ´Â ¹°Áú. 33. ³»ºÎ Ç¥Áعý (internal standarad method) Ư¼ºÀÌ Á¤È®ÇÏ°Ô ¾Ë·ÁÁø ¹°ÁúÀ» ½Ã·á¿¡ °¡ÇϵçÁö ½Ã·á ÁßÀÇ ³óµµ¸¦ ¾Æ´Â ¹°ÁúÀ» Ç¥ÁØÀ¸·Î ÇÏ¿© ¹°ÁúÀ» Á¤·®ÇÏ´Â ¹æ¹ý. 34. ³»ºÎ Ç¥Áؼ± (internal standard line) ¹ß±¤ ºÐ±¤ºÐ¼®¿¡¼ ³»ºÎ Ç¥Áعý¿¡¼ »ç¿ëµÇ´Â ƯÁ¤ÇÑ ¼±½ºÆåÆ®·³. 35. ³ÃÁõ±â ¹æ½Ä (cold vapor type) ¼ö¿Â ¿øÀÚ Áõ±âÀÇ ¿øÀÚ Èí±¤ ºÐ¼®À» À§ÇØ ½Ã·á¿ë¾×À» ȯ¿ø±âÈ ¶Ç´Â °¡¿±âȽÃÅ°´Â ¹æ¹ý. 36. ´Ù±¤ÀÚ ÀÌ¿ÂÈ (ionization with multiple photon absorption) 2°³ ÀÌ»óÀÇ ±¤ÀÚ¸¦ µ¿½Ã¿¡ Èí¼öÇÏ¿© ÀϾ´Â ÀÌ¿ÂÈ. ´Ù±¤ÀÚ ÃµÀÌÀÇ Çϳª. 37. ´Ù»öÈ ÀåÄ¡ (polychrometor) ÀԻ籤À» ºÐ»ê ¼ÒÀÚ¿¡ ÀÇÇØ ºÐ»ê½ÃÄѼ ¸ñÀûÇÏ´Â º¹¼öÀÇ ´Ü»ö±¤À» µ¿½Ã¿¡ ³»´Â ÀåÄ¡. 38. ´Ü»öÈ ÀåÄ¡ (monochtometor) ºÐ¼® ¼ÒÀÚ¿¡ ÀÇÇØ Æ¯Á¤ ÆÄÀåÀÇ ´Ü»ö±¤À» ³»´Â ÀåÄ¡. 39. ´ÜÆÄÀå À̵¿È¿°ú (hyposochromic effect) Èí¼ö ½ºÆåÆ®·³¿¡¼ ºÐÀÚÀÇ ÈÇб¸Á¶ º¯È µî¿¡ ÀÇÇØ ´ÜÆÄÀå À̵¿À» ÀÏÀ¸Å°´Â °Í. 40. ´ëºñ¹ý (ratio method) ÃøÁ¤ Á¤¹Ðµµ¸¦ ³ôÀ̱â À§ÇØ ³óµµÀ» ¾Æ´Â ¿ÜºÎ Ç¥Áع°Áú¿¡ ´ëÇÑ ½ÅÈ£¼¼±â¿Í ¸ñÀû ¹°Áú¿¡ ´ëÇÑ ½ÅÈ£¼¼±âÀÇ ºñ¸¦ »ç¿ëÇÏ¿© °Ë·®¼±À» ÀÛ¼ºÇÏ°í ºÐ¼®ÇÏ´Â ¹æ¹ý. 41. µé¶ä ½ºÆåÆ®·³ (excitation spectrum) ƯÁ¤ ÆÄÀå (º¸Åë ÃÖ´ëÀÇ Çü±¤ ¶Ç´Â Àα¤ÆÄÀå)ÀÇ Çü±¤ ¶Ç´Â Àα¤ °µµ¸¦ µé¶ä ±¤ ÆÄÀåÀÇ ÇÔ¼ö·Î¼ µµ½ÃÇÑ °Í. 42. µé¶ä ¿¡³ÊÁö (excitation energy) ¿øÀÚ¤ýºÐÀÚ¤ýÀÌ¿ÂÀ» µé¶á »óÅ·ΠõÀ̽ÃÅ°´Âµ¥ ÇÊ¿äÇÑ ¿¡³ÊÁö. 43. µîÈí¼öÁ¡ (isosbestic point) 2Á¾·ùÀÇ ÈÇÐÁ¾ÀÌ °øÁ¸ÇÏ´Â °æ¿ì ¾çÀÚ°¡ °°Àº Èí±¤°è¼ö¸¦ ³ªÅ¸³»´Â ÆÄÀå. 44. ¶°µ¹ÀÌ ºû (stray light) ´Ü»öÈ ÀåÄ¡ µîÀ¸·Î ºÐ»êµÇ°í °ËÃâµÈ ºû ¾È¿¡¼ ¿øÇÏ´Â ÆÄÀå ÀÌ¿ÜÀÇ ÆÄÀå ¼ººÐÀÇ ±¤. 45. ¶ì ½ºÆåÆ®·³ (band spectrum) ¾î¶² ÆÄÀ念¿ª ³»¿¡¼ ¶ì ¸ð¾çÀ¸·Î ³ªÅ¸³ª´Â ½ºÆåÆ®·³. ºÐÀÚ ³ª ¿øÀÚ´ÜÀÌ ±× ¼ºÀÎÀÌ´Ù. 46. ¶ó¸¸ ºÐ±¤¹ý (Raman scattering spectroscopy) ¶ó¸¸ »ê¶õ¿¡ ÀÇÇØ ³ªÅ¸³ª´Â ½ºÆåÆ®·³À» ´ë»óÀ¸·Î ÇÏ´Â ºÐ±¤¹ý. ÃøÁ¤ ¹æ¹ý¿¡ µû¶ó °ø¸í ¶ó¸¸, ¿ª ¶ó¸¸, ÇÏÀÌÆÛ ¶ó¸¸, ±¤À½Çâ ¶ó¸¸, À¯µµ ¶ó¸¸ µîÀÇ ºÐ±¤¹ýÀÌ ÀÖ´Ù. µé¶ä±¤¿øÀ¸·Î ·¹ÀÌÀú¿ëÀ» »ç¿ëÇÏ´Â °ÍÀ» ·¹ÀÌÀú ¶ó¸¸ ºÐ±¤¹ýÀ̶ó ÇÑ´Ù. 47. ¶ó¸¸ »ê¶õ (Raman scattering) ÁÖÆļö ¥ôÀÇ ºûÀ» ¹°Áú¿¡ Á¶»çÇÏ¿´À» ¶§ ¹°ÁúÀÇ ±¸Á¶¿¡ µû¶ó Á¤ÇØÁö´Â °íÀ¯ÇÑ Â¡µ¿¼ö ¥ô'¿¡ µû¶ó ÀϾ´Â ÁÖÆļö ¥ô¡¾¥ô'ÀÇ »ê¶õ±¤. 48. ¶÷¹öÆ®ÀÇ ¹ýÄ¢, ºÎ°ÔÀÇ ¹ýÄ¢ (Lamber's law, Bouguer's law) ¸ÅÁúÀÇ ³óµµ°¡ ÀÏÁ¤ÇÑ °æ¿ì , ¸ÅÁúÃþ¿¡ ÀÔ»çÇϱâ Á÷Àü°ú Åõ°úÇÑ Á÷ÈÄÀÇ ºûÀÇ ¼¼±â¸¦ °¢°¢ I0, I ¶ó°í ÇßÀ» ¶§ ´ÙÀ½ ½ÄÀ¸·Î ³ªÅ¸³»´Â °ü°è¸¦ ¸»ÇÑ´Ù. I= I0¤ý10-kcl 49. ·¹ÀÌÀú µé¶ä Çü±¤¹ý (laser induced fluorometry, LIF) ·¹ÀÌÀú¸¦ µé¶ä±¤¿øÀ¸·Î ÇÏ¿© Çü±¤À» °ËÃâÇÏ´Â °üÂû¹æ¹ý ¶Ç´Â ºÐ¼®¹æ¹ý. 50. ·¹Àϸ® »ê¶õ (Rayleigh scattering) ºûÀ» ¹°Áú¿¡ Á¶»ç½ÃÄ×À» ¶§ »ý±â´Â »ê¶õ Çö»ó Áß, Áøµ¿¼ö º¯È¸¦ ¼ö¹ÝÇÏÁö ¾Ê´Â °£¼·¼º »ê¶õÀÇ ÀÏÁ¾. 51. ¸¶ÀÌÅ©·Î Àû¿Ü¼± ºÐ±¤¹ý (infrared microspectromety) Àüü ½Ã½ºÅÛÀÌ ¹Ý»ç±¤¼ÒÀÚ·Î ±¸¼ºµÈ Çö¹Ì°æ¿¡ ÀÇÇØ Àû¿Ü¼± ¿µ¿ª¿¡¼ ÀÛÀº ¿µ¿ªÀÇ ºÐ±¤ ÃøÁ¤À» ÇÏ´Â ¹æ¹ý. ÇÁ¸®¿¡ º¯È¯ Àû¿Ü¼± ºÐ±¤ ±¤µµ°è¿Í Á¶ÇÕ¿¡ ÀÇÇØ ¹Ý»ç Åõ°ú ÃøÁ¤ ¸ðµÎ 10§ Á¤µµÀÇ ÀÛÀº ¿µ¿ª ÃøÁ¤ÀÌ °¡´ÉÇÏ´Ù. 52. ¸¶ÀÌÅ©·Î Çö󽺸¶ ¹ß±¤ºÐ±¤ ºÐ¼®. (microwave induced plasma atomic emission spectrochemical analysis) ¸¶ÀÌÅ©·ÎÆÄ À¯µµ Çö󽺸¶¸¦ ±¤¿øÀ¸·Î ÇÑ ¹ß±¤ ºÐ±¤ºÐ¼®. 53. ¸ð½½·¹ÀÌÀÇ ¹ýÄ¢ (Moseley's law) ¿øÀÚÀÇ °íÀ¯ X¼±ÆÄÀåÀÇ ¿øÀÚ ¹øÈ£ÀÇ °ü°è¸¦ ³ªÅ¸³»´Â ¹ýÄ¢. 54. ¸ô Èí±¤°è¼ö (molar absorptivity) ƯÁ¤ ¹°ÁúÀÇ Èí±¤µµ As¸¦ ÃøÁ¤ ÈÇÐÁ¾ 1¸ô ³óµµ, 1cmÀÇ ¼¿À» »ç¿ëÇßÀ» ¶§ ȯ»êÇÑ °ªÀ¸·Î¼ ÆÄÀå, ¿Âµµ µî¿¡ µû¶ó °áÁ¤µÇ´Â ¹°ÁúÀÇ »ó¼ö ¥ám. ´ÜÀ§´Â §¯-1¤ý§ß-1¤ý1 , ¥ám=As/cl 55. ¸ôºñ¹ý (mole ratio mithod) M°ú A¿¡ ÀÇÇÑ ÈÇÕ¹° M AnÀÌ »ý¼ºµÉ ¶§, MÀÇ ³óµµ¸¦ ÀÏÁ¤ÇÏ°Ô ÇÏ°í AÀÇ ³óµµ¸¦ º¯È½ÃŲ ¸î Á¾·ùÀÇ ¿ë¾×¿¡ ´ëÇÏ¿© Èí±¤µµ¸¦ ÃøÁ¤ÇÏ¿© ±× ¸¸°îÁ¡¿¡¼ Á¶¼ººñ nÀ» ±¸ÇÏ´Â ¹æ¹ý. 56. ¹«Àü±Ø ¹æÀüµî (electrodeless discharge lamp) ±Ý¼ÓÀÇ ÇҷΰÕȹ° µîÀ» ºÒÈ°¼º ±âü¿Í ÇÔ²² ºÀÀÔÇÏ°í Àü±ØÀ» »ç¿ëÇÏÁö ¾Ê°í °íÁÖÆÄ Àü±âÀåÀ¸·Î Á¡µîÇÏ´Â ¹æÀüÆÇ. 57. ¹ÌºÐ ºÐ±¤¹ý (derivative spectrometry) ½ºÆåÆ®·³ÀÇ ¹ÌºÐ°î¼±À» ±¸ÇÏ°í ±× ¹Ì¼Ò º¯È¸¦ ÀÌ¿ëÇÏ´Â ¹æ¹ý. 58. ¹ÌÄ̽¼ °£¼·°è (Michelson interferometer) ÀÔ»ç°úÀ» ºû»ì ºÐÇÒ±â·Î ³ª´©¾î °íÁ¤°Å¿ï°ú À̵¿°Å¿ï·Î ºÐ»ç½ÃŲ ´ÙÀ½ , ´Ù½Ã ÇÕ¼º½ÃÅ°´Â °ÍÀ¸·Î¼ À̵¿ °Å¿ïÀ» ¿òÁ÷ÀÓÀ¸·Î½á ±¤·ÎÂ÷¸¦ º¯È½ÃÄÑ ÀÎÅÍÆä·Î±×·¥À» ¾ò´Â ±¤Çаè. 59. ¹ÙÅÁ º¸Á¤ (¿øÀÚ Èí±¤ ºÐ¼®ÀÇ) (background correction (in atomic absorption spectrometry)) ¹ÙÅÁÈí¼ö¸¦ º¸Á¤ÇÏ¿© ´ë»óÀ¸·Î ÇÏ´Â ¿øÀÚ Áõ±â¸¸¿¡ ÀÇÇÑ Èí±¤µµ¸¦ ¾ò´Â °Í. À̸¦ À§ÇÑ ¹æ¹ýÀ¸·Î ¿¬¼Ó ½ºÆåÆ®·³ ±¤¿ø¹ý, Æí±¤ Áö¸¸¹ý, ºñ°ø¸í ±Ù»ç¼±¹ý, Àڱ⠹ÝÀü¹ý µîÀÌ ÀÖ´Ù. 60. ¹ÙÅÁ »ó´ç ³óµµ (background equivalent concentration, BEC) ¹ÙÅÁ¿¡ ÀÇÇÑ ½ÅÈ£¿Í °°Àº ½ÅÈ£¸¦ ÁÖ´Â ºÐ¼®´ë»ó ¼ººÐÀÇ ³óµµ. 61. ¹ÙÅÁ Èí¼ö (¿øÀÚ Èí±¤ ºÐ¼®ÀÇ) (background absorption (in atomic absorption spectrometry)) ±¤·Î ÁßÀÇ ºÐÀÚ¿¡ ÀÇÇØ Èí±¤ ¶Ç´Â ±¤»ê¶õ¿¡ ÀÇÇÑ ºÐ¼®¼±ÀÇ ¼¼±â°¡ °¨¼ÒÇÏ´Â °Í. 62. ¹Ý»çÀ² (reflectance) ºûÀÌ ¹°ÁúÀÇ Ç¥¸é¿¡¼ ¹Ý»çµÉ ¶§ ÀԻ籤 ¼¼±â¿¡ ´ëÇÑ ¹Ý»ç±¤ ¼¼±âÀÇ ºñÀ². 63. ¹Ý»çÈí¼ö ºÐ±¤¹ý (reflection absorption spectroscopy,RAS) ÀÔ»ç¸é¿¡ Å« ÀԻ簢À¸·Î ÆòÇàÆí±¤À» ÀÔ»ç½ÃÅ´À¸·Î Ç¥¸é¿¡ Á¸ÀçÇÏ´Â ¹°Áú°úÀÇ »óÈ£ ÀÛ¿ëÀÌ Áõ´ëÇÏ°í °¨µµ°¡ Çâ»óµÇ´Â ¹Ý»ç ÃøÁ¤¹ý. 64. ¹ÝÁ×¹ý (paste method) °íü ½Ã·áÀÇ ºÐ±¤Ãø±¤À» Çϱâ À§ÇÑ ½Ã·áÁ¶Á¦¹ýÀÇ Çϳª. ÃøÁ¤ ½Ã·á¸¦ °ö°Ô °¡·ç·Î ¸¸µé°í À¯µ¿ ÆĶóÇÉ µî¿¡ ºÐ»ê½ÃÄÑ ÀÌ°ÍÀ» Åõ¸íÇÑ ÆÇÀ§¿¡ ¹ß¶ó¼ ÃøÁ¤ÇÏ´Â ¹æ¹ý. 65. ¹ß±¤ (luminescence) ¹°ÁúÀÌ ºû, ¿, ÈÇÐ ¹ÝÀÀ µîÀÇ ¿¡³ÊÁö¿¡ ÀÇÇØ µé¶°¼ ÀϾ´Â ¹ß±¤ Çö»ó. 66. ¹ß±¤ ¸é¿ªÃøÁ¤¹ý (luminescence immunlassay) ¸é¿ª ÃøÁ¤¹ý¿¡¼ Ç¥Áö¹°Áú·Î¼ ÈÇÐ ¹ß±¤¼ºÀÇ °ÍÀ̳ª »ý¹° ¹ß±¤¼ºÀÇ °ÍÀ» »ç¿ëÇÏ´Â °Í. 67. ¹ß±¤ ºÐ±¤ ºÐ¼® (emission spectrochemical analysis) Àü±âÀû, ¿Àû,µî °¢Á¾ ¹æ¹ý¿¡ ÀÇÇØ ½Ã·á¸¦ µé¶ß°Ô ÇÏ¿© ¹æ»çµÇ´Â ¿øÀÚ ½ºÆåÆ®·³À» ºÐ±¤±â³ª ºÐ±¤±¤µµ°è·Î °üÃøÇÏ´Â Á¤¼º¤ý Á¤·® ºÐ¼®ÀÇ ÃÑĪ. 68. ¹ß»ö (color development) ÈÇйÝÀÀ, ÈíÂø, Èí¼ö µî¿¡ µû¶ó »ý¼º ¹°Áú¿¡ ƯÀ¯ÇÑ »öÀÌ ³ªÅ¸³ª´Â °Í. 69. ¹ß»ö ½Ã¾à (coloring reagent) ¹ß»ö½ÃÅ°±â À§ÇÏ¿© »ç¿ëÇÏ´Â ½Ã¾à. 70. ¹ß»ö´Ü (chromophore) ºÐÀÚ ³»¿¡¼ Èí¼ö¶ì¸¦ ³ªÅ¸³»´Â ÁÖ¿äÀÎÀÌ µÇ°íÀÖ´Â ¿øÀÚ, ¿øÀÚ´Ü ¶Ç´Â ÀüÀÚ±º. 71. ¹æÃâ¼± (emission line) ¹æ»ç ½ºÆåÆ®·³ Áß¿¡ ³ªÅ¸³ª´Â ¹àÀº ¼±. µé¶á ¿øÀÚ, ÀÌ¿ÂÀÌ ¹Ù´Ú»óÅ·ΠõÀÌÇÒ ¶§ ¹æ»çÇÏ´Â ¿¡³ÊÁöÀÇ ½ºÆåÆ®·³. 72. º£¾îÀÇ ¹ýÄ¢ (Beer's law) ¸ÅÁúÃþÀÇ µÎ²²°¡ ÀÏÁ¤ÇÑ °æ¿ì¿¡ ÀÌ Ãþ¿¡ ÀÔ»çÇϱâ Á÷Àü°ú Åõ°úÇÑ Á÷ÈÄ ºûÀÇ ¼¼±â¸¦ °¢°¢ l0, l¶ó°í ÇÒ ¶§, ´ÙÀ½ ½ÄÀ¸·Î Ç¥½ÃµÇ´Â °ü°è¸¦ ¸»ÇÑ´Ù. ¤Ó0= l ¡¤10KeC½Ä¿¡¼ C: ¸ÅÁúÀÇ ³óµµ, Ke : ±× ¸ÅÁúÀÇ ¾î¶² Á¤ÇØÁø µÎ²²ÀÇ Ãþ 73. º¸Á¶Àü±Ø (¹ß±¤ ºÐ±¤ ºÐ¼®ÀÇ) (auxiliary electrode) ½Ã·á¸¸À¸·Î µÈ Àü±ØÀ» Çü¼ºÇÒ ¼ö ¾ø´Â °æ¿ì¿¡ ½Ã·á¸¦ ¹æÀü ³»¿¡ À¯ÁöÇϱâ À§ÇÑ Àü±Ø . ½Ã·áÀÇ ¼º»ó¿¡ µû¶ó ÀûÇÕÇÑ ¸ð¾çÀÇ °ÍÀ» »ç¿ëÇÑ´Ù. 74. ºÐ±¤ °áÁ¤ (dispersive crystal) X¼±À» ºÐ±¤Çϱâ À§ÇÏ¿© »ç¿ëµÇ´Â °áÁ¤. °áÁ¤ °ÝÀÚ¸éÀÇ °£°ÝÀÇ Å©±â¿¡ µû¶ó Àû¿ëÆÄÀå¹üÀ§°¡ ´Ù¸£´Ù. 75. ºÐ±¤ ±¤µµ°è (spectrophotometer) ºÐ±¤±â¿¡ ÀÇÇØ ºÐ»êµÈ ½ºÆåÆ®·³À» ±¤Àü Ãø±¤¹ýÀ¸·Î ÃøÁ¤ÇÒ ¼ö ÀÖ°Ô ÇÑ ÀåÄ¡. 76. ºÐ±¤ ºÐ¼® ( spectrochemical analysis) ½ºÆåÆ®·³À» ÀÌ¿ëÇÏ¿© ÇÏ´Â Á¤¼º¡¤Á¤·® ºÐ¼®. 77. ºÐ±¤ »çÁø±â (spectrograph) ºÐ±¤±â¿¡ ÀÇÇØ ºÐ»êµÈ ½ºÆåÆ®·³À» »çÁø¹ýÀ¸·Î ±â·ÏÇÏ´Â ÀåÄ¡. 78. ºÐ±¤±â ((1)spectrograph, spectrometer (2)spectroscope) (1)1 °³ ±¤¿øÀ¸·Î ºÎÅÍÀÇ ºûÀ» ºÐ»ê½ÃÄÑ 1°³ ÃÊÁ¡¸é À§¿¡ ÆÄÀå¼øÀ¸·Î ½½¸´»óÀ» »ý±â°Ô ÇÏ´Â ÀåÄ¡. (2) (1)ÀÇ ÀåÄ¡¿¡¼ ½ºÆåÆ®·³À» ´«À¸·Î °üÂûÇÒ ¼ö ÀÖµµ·Ï ÇÑ ÀåÄ¡. 79. ºÐ±¤ºÐ¼®¿¡¼ ¿ø¼ÒÀÇ Á¤·®¿¡ ÀÌ¿ëµÇ´Â ¼±½ºÆåÆ®·³. (analytical line) ºÐ±¤ºÐ¼®¿¡¼ ¿ø¼ÒÀÇ Á¤·®¿¡ ÀÌ¿ëµÇ´Â ¼±½ºÆåÆ®·³. 80. ºÐ¹«±â (nebulizer) ½Ã·á ¿ë¾×À» °ø±â, ¾Æ¸£°ï µîÀ¸·Î ºÐ¹«ÇÏ¿© ¿¡¾î·ÎÁ¹¿¡ °¡±î¿î ¹Ì¼¼ÇÑ ÀÔÀÚ·Î ¸¸µå´Â ÀåÄ¡. 81. ºÐ»ê ¼ÒÀÚ (dispersive device) °¢Á¾ ÆÄÀå ¼ººÐÀÇ ºûÀ» ºÐ»ê½ÃÅ°±â À§ÇÑ ±¤ÇÐ ¼ÒÀÚ. 82. ºÐÀÚ±¤µµ ºÐ¼®¹ý (molecular absorption spectrophotometry) ÆÄÀå 180~1000 nmÀÇ Æ¯Á¤ ÆÄÀå¿¡¼ ºûÀÇ Èí¼ö¸¦ ÃøÁ¤ÇÏ¿© Á¤¼º¤ýÁ¤·®À» ÇÏ´Â ¹æ¹ý. 83. ºÐÇØ (ºÐ±¤±âÀÇ) (resolution (of spectrometer)) ´Ü»öÈ ÀåÄ¡¿¡¼ ³ª¿À´Â ºûÀÇ ½ºÆåÆ®·³ ³ªºñ. 84. ºÐÇØ´É (±¤ºÐ ºÐ¼®ÀÇ) (resolving power (in photometric analysis)) ÀÎÁ¢ÇÑ 2°³ÀÇ ¹æÃâ¼± ½ºÆåÆ®·³À» º°°³ÀÎ °ÍÀ¸·Î¼ ½Äº°ÇÒ ¼ö ÀÖ´Â ´É·Â. ½Äº°°¡´ÉÇÑ ÃÖ¼ÒÇÑÀÇ ÆÄÀåÂ÷·Î Ç¥½ÃÇÑ´Ù. 85. ºÒ²É ¿øÀÚÈí±¤ ºÐ¼® (flame atomic absorption spectrometry) ºÒ²É (ÈÇкҲÉ)À» »ç¿ëÇÏ´Â ¿øÀÚ Èí±¤ ºÐ¼®. 86. ºê¶ó±×½Ä (Bragg's equation) °áÁ¤ÀÇ °ÝÀÚ°£°Ý, X¼±ÀÇ ÀԻ簢 ¹× ȸÀýÂ÷¼ö¿Í ¹Ý»ç X¼± ÆÄÀåÀÇ °ü°è¸¦ ³ªÅ¸³½ ½Ä. 87. ºñ·Ê °è¼ö°ü (proportional cornter) ÀÔ»ç X¼± ¿¡³ÊÁö¿¡ ºñ·ÊÇÏ´Â ³ôÀÌÀÇ ÆÞ¼ö¸¦ ¹ß»ýÇÏ´Â °è¼öÆÇ. 88. ºñºÐ»ê (non-dispersion) ƯÁ¤ ÆÄÀå¶ì¸¦ ÃøÁ¤Çϱâ À§ÇÏ¿© ºÐ»ê ¼ÒÀÚ¸¦ »ç¿ëÇÏÁö ¾Ê°í, ±¤ÇÐÇÊÅÍ, ¼±Åüº °ËÃâ±â µîÀ» »ç¿ëÇÔÀ¸·Î½á ÆÄÀå ºÐ»ê°ú ¶È°°Àº È¿°ú¸¦ ¾ò´Â °Í. 89. ºñºí²É ¿øÀÚ Èí±¤ ºÐ¼® (flameless atomic absorption spectrometry) ºÒ²É(ÈÇкҲÉ)À» »ç¿ëÇÏÁö ¾Ê´Â ¿øÀÚ Èí±¤ ºÐ¼® . Àü±â°¡¿ ¹æ½Ä°ú ³ÃÁõ±â ¹æ½ÄÀÌ ÀÖ´Ù. 90. ºñ»ö ºÐ¼® (colorimetric analysis) ½Ã·á¹°ÁúÀÇ Åõ°ú±¤ ¶Ç´Â ¹Ý»ç±¤¿¡ ÀÇÇÑ »öÁ¶³ª »öÀÇ ³óµµ µîÀ» Ç¥ÁØ ¿ë¾× µî°ú ºñ±³ÇÏ¿© Á¤¼º¤ýÁ¤·®ºÐ¼®À» ÇÏ´Â °Í. 91. ºñŹ¹ý (turbidimetry) ŹÇÑ ¹°Áú¿¡ ´ëÇÏ¿© ±× »ê¶õ±¤ÀÇ ¼¼±â ȤÀº Źµµ¿¡ ÀÇÇÑ ºû ¼¼±âÀÇ °¨¼è ¶Ç´Â ¾çÀÚÀÇ ºñ¸¦ ÃøÁ¤ÇÔÀ¸·Î½á ±× ¹°ÁúÀÇ ³óµµ¸¦ ÃøÁ¤ÇÏ´Â ¹æ¹ý. 92. »çÁø Ãø±¤¹ý(¹ß±¤ºÐ±¤¼®ÀÇ) (spectrophotographic (in emission spectrochemical analysis)) ºÐ±¤±â¿¡¼ ºÐ¼®µÈ ½ºÆåÆ®·³À» »çÁø°¨±¤ Àç·á¿¡ ³ëÃâ½ÃÄѼ ½ºÆåÆ®·³ »çÁøÀ» ¾ò´Â ¹æ¹ý. 93. »êÈ ºÒ²É (oxidative flame) °úÀ×ÀÇ »êȼº ±âü°¡ Á¸ÀçÇÏ¿© »êȼº ºÐÀ§±â°¡ µÇ¾î ÀÖ´Â ÈÇкҲÉ. 94. »ó°ü±¤ À½Ç⠺б¤¹ý (correlational photoacoustic spectrometry, c-PAS) µé¶á ±¤ÀÇ ÁÖÆļö¸¦ º¯Á¶½ÃÄÑ ¾ò¾îÁø ½ÅÈ£¸¦ Çؼ®ÇÏ¿© ±íÀÌ ¹æÇâÀÇ Á¤º¸¸¦ ¾ò´Â ±¤À½Ç⠺б¤¹ý. 95. »ó´ë Àü±Ø (¹ß±¤ ºÐ±¤ ºÐ¼®ÀÇ) (counter electrode (in emission spectrochemical analysis)) ¹ß±¤ ºÐ±¤ºÐ¼®¿¡¼ ¹æÀüÀ» Çü¼ºÇÏ´Â 1½ÖÀÇ Àü±Ø Áß, ½Ã·áÀü±Ø ¶Ç´Â º¸Á¶Àü±ØÀÌ ¾Æ´Ñ ÂÊÀÌ Àü±Ø. 96. »ó¹Ý ¹ýÄ¢ÀÇ ºÒ¼º¸³ (»çÁø Ãø±¤¹ýÀÇ) (counter electrode (in emission spectrochemical analysis)) »çÁø Ãø±¤¹ý¿¡¼ º¹»ç¼±ÀÇ ¼¼±â°¡ ±ØÈ÷ ¼¾ °æ¿ì¿Í ¾àÇÑ °æ¿ì ¹× ³ëÃ⠽ð£ÀÌ ±ØÈ÷ ªÀº °æ¿ì¿Í ±ä °æ¿ì¿¡ »ó¹Ý¹ýÄ¢ÀÌ ¼º¸³ÇÏÁö ¾Ê´Â Çö»ó, Áï ºûÀÇ ¼¼±â¿Í ³ëÃâ½Ã°£ÀÇ °öÀÌ Èæȵµ¿¡ ºñ·ÊÇÏÁö ¾Ê´Â Çö»ó. 97. »ý¹° ¹ß±¤ (bioluminescence) »ý¹° ÈÇйÝÀÀ¿¡ ¼ö¹ÝÇÏ¿© ÀϾ´Â ¹ß±¤. 98. »ý¹° ¹ß±¤¹ý (bioluminescence method) »ý¹°¹ß±¤À» ÀÌ¿ëÇÑ ºÐ¼®¹æ¹ý. ½Ã·á¿¡ »ý¹° ¹ß±¤¼º È¿¼Ò, ¹Ì»ý¹° µîÀ» ÀÛ¿ë½ÃÄÑ ¹æÃâµÇ´Â ±¤·®À» ÃøÁ¤ÇÏ¿© ÃøÁ¤ ´ë»ó ¹°ÁúÀÇ ³óµµ ¶Ç´Â ¾çÀ» ±¸ÇÑ´Ù. 99. ¼¶±¤ °è¼ö±â (scintillation counter) Nal (Ti) µîÀÇ ¼¶±¤Ã¼¿¡ÀÇÇØ ÀÔ»ç X¼±À» °¡½Ã¼± ¶Ç´Â Àڿܼ± ¿µ¿ªÀÇ ±¤ÆÞ½º·Î º¯È¯½ÃÄÑ °è¼öÇÏ´Â °ËÃâ±â. 100. ¼¼Æ÷ ºÐ·ù (cell sorting) Ç÷Π»çÀÌÆ®¸ÞÆ®¸®¸¦ ÀÌ¿ëÇÏ¿© ƯÁ¤ ¼¼Æ÷ÀÔÀÚ¸¦ °¢°³·Î ºÐ¸®¤ý¼öÁý ÇÏ´Â °Í.
101. ¼Ò±¤(Çü±¤±¤µµ ºÐ¼®ÀÇ) (quenching(in fluorescence spectrometry)) ºû¿¡ ÀÇÇØ µé¶á ºÐÀÚ°¡ ´Ù¸¥ ºÐÀÚ¿Í Ãæµ¹Çϰųª ÈÇйÝÀÀ¿¡ ÀÇÇØ Çü±¤À» ¹ßÇÏ´Â È°¼ºÀ» »ó½ÇÇÏ´Â °Í. 102. ¼Óºó À½±Øµî (hollow cathode lamp) ºÐ¼® ´ë»ó¿ø¼Ò¸¦ Æ÷ÇÔÇÏ´Â ¼Óºó À½±ØÀ» Àú¾ÐÀÇ ³×¿Â µî°ú ÇÔ²² ºÀÀÔÇÑ ¹æÀü°ü. ¿øÀÚ Èí±¤ºÐ¼® µîÀ» À§ÇÑ ±¤¿øÀ¸·Î¼ »ç¿ëµÈ´Ù. 103. ¼ö¼Ò ¹æÀü°ü (hydrogen lamp) Áø°ø°ü ¾È¿¡ ±ØÈ÷ ³·Àº ¾Ð·ÂÀ¸·Î ºÀÀÔÇÑ ¼ö¼Ò Áß¿¡¼ÀÇ ¾ÆÅ© ¹æÀüÀ» ÀÌ¿ëÇÏ´Â ¹æÀü°ü. Àڿܼ±ºÎÀÇ ½ºÆåÆ®·³ ±¤¿øÀ¸·Î¼ »ç¿ëµÈ´Ù. 104. ¼ö¼Òȹ° ¹ß»ý¹ý. (hydride generation method) ½Ã·á¿ë¾× Áß ºÐ¼®´ë»ó ¼ººÐ(º¸±â¸¦ µé¸é ºñ¼Ò, ¼¿·», ¾ÈƼ¸ó µîÀÇ ÈÇÕ¹°)À» ºÒ²É, Çö󽺸¶ ¶Ç´Â Èí¼ö¼¿¿¡ µµÀÔÇÏ°í ºÐ¼®Çϱâ À§ÇÏ¿© ȯ¿øÇÏ¿© ¼ö¼Ò ÈÇÕ¹°·Î ÇÏ´Â ¹æ¹ý. 105. ½ºÆÄÅ© ¹æÀü ¹ß±¤ ºÐ±¤ºÐ¼® (spark source atomic emission spectrochemical analysis) ½ºÆÄÅ© ¹æÀüÀ» ±¤¿øÀ¸·Î ÇÑ ¹ß±¤ ºÐ±¤ºÐ¼®. 106. ½ºÆÄÅ©¼± (spark line) ½ºÆÄÅ© ¹æÀü¿¡ ÀÇÇØ µé¶á ÀÌ¿ÂÀÌ ¹æ»çÇÏ´Â ¼±½ºÆåÆ®·³. 107. ½ºÆÒ Á¶Á¤¿ë ±âü(±âü ºÐ¼®°è) (span gas (for gas analyzer)) ºÐ¼®°èÀÇ ´«±ÝÀ» Á¤Çϰųª ´«±Ý±³Á¤ ÀÌ¿ÜÀÇ ½ÃÇè¿¡¼ ½ºÆÒ ±³Á¤¿ë ±âü ´ë½Å¿¡ »ç¿ëÇÏ´Â ±âü 108. ½ºÆåÆ®·³ (spectrum) ÇϳªÀÇ ¹æ»ç¿ø¿¡¼ ¹ßÇÏ´Â ÀüÀÚÆÄÀÇ ¹æ»ç¸¦ ÇÁ¸®Áò, ȸÀý°ÝÀÚ µîÀÇ ºÐ»ê ¼ÒÀÚ¿¡ ÀÇÇØ ºÐ»ê½ÃÄÑ ¾ò¾îÁø °Í. 109. ½ºÆåÆ®·³ ³ªºñ (spectral bandwidth) ±¤ÇÐ ½Ã½ºÅÛÀÇ Ãⱸ ½½¸´À» ³ª¿Â ºû»ìÀÇ ³ªºñ¸¦ ÆÄÀå ¶Ç´Â ¿¡³ÊÁöµîÀ¸·Î Ç¥½ÃÇÑ °Í. 110. ½ºÆåÆ®·³ ºÐÆ÷ °î¼± (spectral distribution curve) ±¤¿øÀ¸·ÎºÎÅÍÀÇ ¹æ»ç ¼¼±â¸¦ ÆÄÀå, ¿¡³ÊÁö µîÀÇ ÇÔ¼ö·Î¼ µµ½ÃÇÑ °Í. 111. ½ºÆåÆ®·³ ¼øµµ(ºû»ìÀÇ) (spectral purity (of light beam)) ÇϳªÀÇ ºû»ì Áß¿¡ Æ÷ÇԵǾî ÀÖ´Â ¹æ»çÀÇ ÆÄÀå ³ªºñ. ÀÌ°ÍÀÌ ÀÛÀ»¼ö·Ï ½ºÆåÆ®·³ÀÇ ¼øµµ°¡ ³ô´Ù. 112. ½½¸´ (slit) ±¤Çа迡¼ ºû»ìÀ» ±ÔÁ¦Çϱâ À§ÇÏ¿© ¼³Ä¡µÈ Á¼Àº °£°Ý. 113. ½½¸´ ³ªºñ (slit width) ÆòÇàÇÏ°Ô ¿·Á ÀÖ´Â ½½¸´ÀÇ °£°Ý. §®¶Ç´Â §´ÜÀ§·Î Ç¥½ÃÇÑ´Ù. 114. ½Ã°£ ºÐÇØ ºÐ±¤¹ý (time resolved spectroscopy) ±ØÈ÷ ªÀº ½Ã°£ÀÇ ½ºÆåÆ®·³À» ÃëÇÏ´Â °Í ¹× ±×°ÍÀ» ½Ã°è¿ÀûÀ¸·Î °üÂûÇÏ´Â °Í. ÇѹøÀÇ ÃøÁ¤½Ã°£ÀÌ 10-9ÃÊ ¼öÁØÀÎ °æ¿ì ³ª³ëÃÊ ºÐ±¤, 10-12ÃÊ ¼öÁØÀÎ °æ¿ì ÇÇÄÚÃÊ ºÐ±¤ µîÀ̶ó°í ÇÑ´Ù. 115. ½Ã·á Àü±Ø( ¹ß±¤ ºÐ±Ø ºÐ¼®ÀÇ) (sample electrode (in emission spectrochemical analysis)) ºÐ¼®½Ã·á ±× ÀÚü·Î Á¶Á¦ÇÑ ¹æÀüÀü±Ø. º¸Åë, È濬Á¦ »ó´ëÀü±Ø°ú Á¶ÇÕÇÏ¿© »ç¿ëÇÑ´Ù. 116. ½Ã·á¼¿ (¹ß°ü ºÐ±¤ ºÐ¼®ÀÇ) (smple cell(in molecular absorption spectrometry)) ½Ã·á ¿ë¾×À» ³ÖÀº Èí¼ö¼¿. 117. ½ÃÂ÷ ÃøÁ¤¹ý (Èí±¤±¤µµ ºÐ¼®¹ýÀÇ) (differential mes) ´ë´ÜÈ÷ ÀÛµçÁö Å« Èí±¤µµ¸¦ Á¤¹ÐÇÏ°Ô ÃøÁ¤Çϱâ À§ÇØ , ½Ã·á¿ë¾×ÀÇ Èí±¤µµº¸´Ù ¾à°£ Å©µçÁö ÀÛÀº Èí±¤µµ¸¦ ³ªÅ¸³»´Â ³óµµ¸¦ ¾Æ´Â ¿ë¾×À» 100¸ÂÃã¿ëÀ¸·Î ´ëÁ¶¾×À¸·Î¼ »ç¿ëÇÏ´Â ÃøÁ¤¹æ¹ý. 118. ½ÅÈ£ ´ë ¹ÙÅÁ¼±ºñ (signal-to-background ratio , SB ratio) ¼ø½ÅÈ£¼¼±â¿Í ¹ÙÅÁ¼º ¼¼±âÀÇ ºñÀ². 119. ½ÌÅ©·ÎÆ®·Ð º¹»ç (synchrotron radiation, SR) ÀüÀÚ °¡¼Ó±âÀÇ ÀÏÁ¾ÀÎ ÀüÀÚ ½ÌÅ©·ÎÆ®·Ð¿¡¼ÀÇ º¹»ç. °¡½Ã¼± ¿µ¿ª¿¡¼ X¼± ¿µ¿ª¿¡ ¹ÌÄ¡´Â ³ÐÀº ¹üÀ§ÀÇ ¿¬¼Ó±¤ÀÌ ¾ò¾îÁø´Ù. 120. ¾ÆÅ© ¹æÀü ¹ß±¤ ºÐ±¤ ºÐ¼® (arc discharge atomic emission spectrochemical analysis) Àü±Ø°£¿¡ ¾ÆÅ©¹æÀüÀ» ÀÏÀ¸ÄÑ ÀÌ°ÍÀ» ±¤¿øÀ¸·Î ÇÏ´Â ¹ß±¤ºÐ±¤ºÐ¼®. 121. ¾ÆÅ©¼± (arc line) ¾ÆÅ©³ª ºÒ²É¿¡ ÀÇÇØ µé¶á Áß¼º¿øÀÚ¿¡°Ô ¹æ»çµÇ´Â ¼±½ºÆåÆ®·³. 122. ¿¡³ÊÁö ºÐ»ê¹æ½Ä (energy dispersive method) ±¤ÇÐÀûÀÎ ºÐ»ê¹æ½ÄÀ» »ç¿ëÇÏÁö ¾Ê°í, X¼± ¿¡³ÊÁö¿¡ ºñÇÏ¿© Àü±â ½ÅÈ£¸¦ ¼±º°ÇÏ¿© ºÐ±¤(¿¡³ÊÁö ¼±º°)ÇÏ´Â ¹æ½Ä. 123. ¿ª¼± ºÐ»ê (reciprocal linear dispersion) ºÐ±¤±âÀÇ ºÐ»êµµ Ç¥½Ã¹æ¹ýÀÇ Çϳª. ºÐ±¤±âÀÇ ÃÊÁ¡¸é¿¡¼ d¥ëÀÇ ÆÄÀåÂ÷¸¦ °®´Â ºûÀÌ dxÀÇ °Å¸®¸¦ °¡Áú ¶§¸¦ ÀǹÌÇϸç d¥ë/dx·Î Ç¥½ÃµÈ´Ù. 124. ¿¬¼Ó º¯È¹ý (continuous variation method) M°ú A¿¡ ÀÇÇØ ÈÇÕ¹° M AnÀÌ »ý¼ºµÉ ¶§ , M°úAÀÇ Àüü ³óµµ¸¦ ÀÏÁ¤ÇÏ°Ô À¯ÁöÇÏ°í, °¢°¢ÀÇ È¥ÇÕºñ¸¦ º¯È½ÃŲ ¸î Á¾·ùÀÇ ¿ë¾×¿¡ ´ëÇÏ¿© Èí±¤µµ¸¦ ÃøÁ¤ÇÏ°í ±× Ãִ븦 ³ªÅ¸³»´Â Á¡À¸·ÎºÎÅÍ Á¶¼ººñ nÀ» ±¸ÇÏ´Â ¹æ¹ý. 125. ¿¬¼Ó ½ºÆåÆ®·³ (continuous spectrum) ¿¡³ÊÁöÀÇ º¹»ç°¡ ¾î¶² ÆÄÀ念¿ª¿¡ °ÉÃļ ¿¬¼ÓµÇ°í ÀÖ´Â °æ¿ìÀÇ ½ºÆåÆ®·³. 126. ¿·»Áî ºÐ±¤¹ý (thermal lens spectrometry, TLS) ½Ã·áÀÇ ±¼Àý·üÀÌ ±¤Èí¼ö¿¡ ÀÇÇÑ ¿¹ß»ýÀ¸·Î ±Ø¼ÒÀûÀ¸·Î º¯ÈÇÏ´Â °ÍÀ» ÀÌ¿ëÇÏ´Â ºÐ±¤¹ý. ¹Ì¾à Èí¼öÃøÁ¤¹ýÀÇ ÀÏÁ¾. 127. ¿µÁ¡ Á¶Á¤ (Åõ°ú ÆÛ¼¾Æ®ÀÇ) (zero adjustment (of percent transmission)) Åõ°ú ÆÛ¼¾Æ® ´«±Ý Áö½Ã°èÀÇ Áö½Ã¸¦ ¿µÀÇ ´«±Ý¿¡ ¸ÂÃß´Â Á¶ÀÛ. 128. ¿µÁ¡ Á¶Á¤¿ë ±âü (±âü ºÐ¼®°èÀÇ) (zero gas (for gas analyzer)) ºÐ¼®°èÀÇ ´«±ÝÀ» Á¤Çϰųª ´«±Ý±³Á¤ ÀÌ¿ÜÀÇ ½ÃÇè¿¡¼ ¿µÁ¡ ±³Á¤¿ë ±âü ´ë½Å¿¡ »ç¿ëÇÏ´Â ±âü. 129. ¿¹ºñÈ¥ÇÕ ¹ö³Ê (permix burner) ¿¬·á±âü, »êÈÁ¦ ±âü ¹× ½Ã·á ¿ë¾×ÀÇ ¾È°³¸¦ È¥ÇÕ ¿¬¼Ò½ÃÄѼ ¿øÀÚÈÇÏ´Â ¹æ½ÄÀÇ ¹ö³Ê. 130. ¿À¸ñ ºÐ±¤¼ÒÀÚ( X¼±ÀÇ) (concave dispersive element (for X-ray analysis)) °áÁ¤ °ÝÀÚÀÇ ºê·¡±× ¹Ý»ç¸¦ ÀÌ¿ëÇÏ¿© X¼±À» ºÐ±¤Çϱâ À§ÇÑ ¿À¸ñÇÑ ¸ð¾çÀÇ ¼ÒÀÚ. 131. ¿ÜÀå ±âü (¿øÀÚ Èí±¤ ºÐ¼®ÀÇ) (sheath gas (in atomic absorption spectrometry)) ºÐ¼® Á¶À۽à ºÐ¼® ´ë»ó ¿ø¼Ò³ª ¿øÀÚȺΠÁÖº¯ ÀçÁúÀÇ »êȸ¦ ¹æÁöÇϱâ À§ÇÏ¿© »ç¿ëÇÏ´Â ºÒȼº ±âü 132. ¿ë¸Å È¿°ú (solvent effect) ¿ë¾×ÀÇ Èí¼ö ¶Ç´Â ¹ß±¤ ½ºÆåÆ®·³¿¡¼ ¿ëÁú ºÐÀÚ¿¡ ƯÀ¯ÇÑ ½ºÆåÆ®·³ÀÌ ¿ë¸ÅÀÇ Á¾·ù¿¡ µû¶ó ÆÄÀå À̵¿À̳ª ½ºÆåÆ®·³ÀÇ ¸ð¾çÀ̳ª ¼¼±â¿¡ º¯È°¡ ³ªÅ¸³ª´ÂÁö ¶Ç´Â ´Ù¸¥ ÆÄÀ念¿ª¿¡ »õ·Î¿î ½ºÆåÆ®·³ÀÌ ³ªÅ¸³ª´Â Çö»ó. 133. ¿î¹Ý ±âü (carrier gas) ½Ã·á¿ë¾× ȤÀº ±× ¾È°³ ¶Ç´Â ºÐ¼® ´ë»ó ¼ººÐÀÇ Áõ±â¸¦ ¿øÀÚȺÎ, Çö󽺸¶ µî¿¡ µµÀÔÇϱâ À§ÇÑ ±âü. 134. ¿ø Æí±¤ 2»ö¼º (circular dichroism, CD) ±¤ÇÐ À̼ºÁúüÀÇ ±¤ÇÐ Èí¼ö¶ì ºÎ±Ù¿¡¼ ¿øÆí±¤ Á¿ìÀÇ Èí¼öÂ÷. 135. ¿øÀÚ ½ºÆåÆ®·³ (atomic spectrum) ¿øÀÚ°¡ ¹æ»ç ¶Ç´Â Èí¼öÇÏ´Â ÀüÀÚÆÄÀÇ ½ºÆåÆ®·³. 136. ¿øÀÚ ½ºÆåÆ®·³ ºÐ¼® (analytical atomic spectrometry) ¿øÀÚ ½ºÆåÆ®·³À» ÃøÁ¤ÇÏ¿© ¿ø¼Ò¸¦ Á¤¼º¤ýÁ¤·®ÇÏ´Â ¹æ¹ý. 137. ¿øÀÚÇü±¤ ºÐ±¤¹ý (atomic absorption spectrometry) µé¶á ¿øÀÚ°¡ ³·Àº ¿¡³ÊÁö ÁØÀ§·Î õÀÌÇÒ ¶§, ¹æÃâµÇ´Â 2Â÷±¤(¿øÀÚÇü±¤)À» °ËÃâÇÏ´Â ºÐ±¤¹ý 138. ¿øÀÚÈí±¤ ºÐ¼®¹ý (atomic absorption spectrometry) ½Ã·á Áß¿¡ ÇÔÀ¯µÇ´Â ºÐ¼® ´ë»ó¿ø¼Ò¸¦ ºÒ²É, Àü±â°¡¿ ¶Ç´Â ÈÇйÝÀÀ¿¡ ÀÇÇØ ¿øÀÚȽÃÅ°°í ±× ¿øÀÚ Áõ±âÃþÀÌ Èí±¤µµ¸¦ ÃøÁ¤ÇÕÀ¸·Î½á ºÐ¼® ´ë»ó ¿ø¼ÒÀÇ ³óµµ¸¦ ±¸ÇÏ´Â ¹æ¹ý. ºÒ²É ¿øÀÚ Èí±¤ºÐ¼®°ú ºñºÒ²É ¿øÀÚÈí±¤ ºÐ¼®ÀÌ ÀÖ´Ù. 139. À¯µµ°áÇÕ °íÁÖÆÄ Çö󽺸¶ (inductively coupled plasma, ICP) ÄÚÀÏ¿¡ 300MHz ÀÌÇÏÀÇ Æ¯Á¤ °íÁÖÆÄÀÇ Àü·ù¸¦ Èê·Á , ÀüÀÚ±â À¯µµ¿¡ ÀÇÇØ ¹ß»ýÇÑ Àü±âÀåÀ¸·Î ÄÚÀÏ ³»ÀÇ ±âü¸¦ ÀÌ¿ÂȽÃÄÑ ¾ò¾îÁö´Â °í¿ÂÀÇ Çö󽺸¶ 140. À¯µµ°áÇÕ °íÁÖÆÄ Çö󽺸¶ ¹ß±¤ ºÐ±¤ ºÐ¼® (inductively coupled plasma (ICP)atomic emission spectrochemical analysis) À¯µµ°áÇÕ °íÁÖÆÄ Çö󽺸¶¸¦ ±¤¿øÀ¸·Î ÇÑ ¹ß±¤ ºÐ±¤ ºÐ¼®. 141. À̿¼± (ionic line) µé¶á ÀÌ¿ÂÀÌ ¹æ»çÇÏ´Â ¼±½ºÆåÆ®·³. 142. Àα¤ (phosphrescence) ¹°ÁúÀÇ ºÐÀÚ°¡ ºû¿¡ ÀÌÇØ µé¶á 1ÁßÇ× »óÅ·Πµé¶ß°í, ±×°ÍÀÌ µé¶ä 3ÁßÇ× »óÅ·Π¿Å±ä ÈÄ , ¹Ù´Ú »óÅ·ΠõÀÌÇÒ ¶§ ¹ß»ýÇÏ´Â ºû. 143. Àڿܼ± ½ºÆåÆ®·³ (ultraviolet spectrum) ÀüÀÚÆÄÀÇ ¹æ»ç Áß¿¡¼ ¾à 200nm¿¡¼ 400nm±îÁö ÆÄÀå ¿µ¿ªÀÇ ½ºÆåÆ®·³. 144. ÀÚü ¹ÝÀü (self reversal) ¹æÃâ¼±ÀÇ ÀÚü Èí¼ö°¡ °ÇØÁ®¼ ±× Á߽ɺÎÀÇ ¹æ»ç ¼¼±â°¡ ¿µ ¶Ç´Â ¿µ¿¡ °¡±î¿î Çö»ó. 145. ÀÚü Èí¼ö (self absorption) 1°³ÀÇ ¹æÃâ¼±¿¡¼ ±× ¹æÃâ¼±À» ¹æÃâÇÏ´Â ¹°Áú°ú °°°í, ³·Àº ¿¡³ÊÁö »óÅ¿¡ ÀÖ´Â ¹°ÁúÀÌ ¹æ»ç ¿¡³ÊÁö¸¦ Èí¼öÇÏ´Â Çö»ó. 146. ÀåÆÄÀå À̵¿È¿°ú (bathochromic effect) Èí¼ö ½ºÆåÆ®·³¿¡¼ ºÐÀÚÀÇ ÈÇб¸Á¶ º¯È¿¡ µû¶ó Àû»öÀ̵¿À» ÀÏÀ¸Å°´Â °Í. 147. ÀðÅ°³ëÀÇ ¿ìÀ§¼º (Jaquinot's advantage) °£¼· ºÐ±¤¹ý¿¡¼´Â ½½¸´À» »ç¿ëÇÏÁö ¾ÊÀ¸¹Ç·Î ¸¹Àº ¾çÀÇ ºûÀ» ÀÌ¿ëÇÒ ¼ö Àֱ⠶§¹®¿¡ ¹à±â Á¡¿¡¼ À¯¸®ÇÏ°í ´ë´ÜÈ÷ ¾àÇÑ ±¤ÀÇ ÃøÁ¤¿¡ À¯¸®ÇÏ´Ù´Â °Í. 148. Àû»ö À̵¿ (red shift) ÃÖ´ë Èí¼öÆÄÀåÀÌ ÀåÆÄÀåÂÊÀ¸·Î À̵¿ÇÏ´Â °Í. 149. Àû¿Ü¼± ºÐ±¤ ±¤µµ¹ý (infared spectrophotometry) Àû¿Ü¼± Èí¼ö ½ºÆåÆ®·³À» ÃøÁ¤ÇÏ¿© Á¤¼º¤ýÁ¤·®À» ÇÏ´Â ºÐ¼® ¹æ¹ý. 150. Àû¿Ü¼± Èí¼ö ½ºÆåÆ®·³ (infrared absorption spectrum) Àû¿Ü¼±ºÎ¿¡ ³ªÅ¸³ª´Â Èí¼ö ½ºÆåÆ®·³. 151. Àü±â °¡¿¹æ½Ä(¿øÀÚ Èí±¤ ºÐ¼®ÀÇ ) (electrothermal type (in atomic absorption spectrometry)) ½Ã·á¸¦ È濬À̳ª ³»¿ ±Ý¼ÓÀ» ¹ß¿Ã¼·Î ÇÏ´Â ³ë ¾È¿¡¼ °ÇÁ¶¤ýȸȤý¿øÀÚȽÃÅ°´Â ¹æ½Ä. 152. Àü¹Ý»ç °¡¼â¹ý (attenuated total reflection method) ±¼Àý·üÀÌ Å« ÇÁ¸®Áò¿¡ ºÐ¼® ÆÄÀåÀÌ ºûÀ» ÀÓ°è°¢ ÀÌ»óÀ¸·Î ÀÔ»ç½ÃÄÑ ÇÁ¸®Áò°ú ½Ã·á °è¸é¿¡¼ Àü¹Ý»ç¸¦ ÀÏÀ¸Å°°Ô ÇÏ¿© ½Ã·áÀÇ Èí¼ö ½ºÆåÆ®·³À» ¾ò´Â ¹æ¹ý. 153. ÀüÀÚ °áÇÕ ¿¡³ÊÁö (electron binding energy) ±¤ÀüÀÚ ºÐ±¤¹ýÀÇ ¿¡³ÊÁöÃøÀ» ´«±Ý ¸Å±â±â À§ÇÏ¿© »ç¿ëµÇ´Â ¾ç. °¢ ±¸¼ºÀüÀÚÀÇ °áÇÕ ¼¼±â¸¦ ÀǹÌÇϸç eV´ÜÀ§·Î Ç¥½ÃÇÑ´Ù. 154. ÀüÀÚŽħ ¸¶ÀÌÅ©·Î ºÐ¼® (electron beam microanalysis, EPMA) °¡´Ã°Ô ÁÙÀÎ ÀüÀÚ»ìÀ» ½Ã·á¿¡ Á¶»çÇÏ¿© ¾ò¾îÁö´Â X¼±À» °ËÃâÇÏ´Â ºÐ±¤¹æ¹ý. 155. Á¤Á¦¹ý (tablet method, pellet method) ÃøÁ¤ ½ÃÇ¥¸¦ °í¿î °¡·ç·Î ¸¸µç ´ÙÀ½, ÃøÁ¤ ÆÄÀå ¹üÀ§¿¡¼ ºûÀÇ Èí¼ö°¡ ÀûÀº ¹ÌºÐ¸» »óÅÂÀÇ ¸Åü Áß¿¡ ±ÕÀÏÇÏ°Ô È¥ÇÕÇÑ ÈÄ, Á¤Á¦·Î ¸¸µé¾î ÃøÁ¤ÇÑ´Â ¹æ¹ý. 156. Á¶»ö´Ü (auxochrome) ¹ß»ö´Ü°ú µ¿ÀϺÐÀÚ¿¡ Á¸ÀçÇϸç, °¡½Ã¼±À» Èí¼öÇϴµ¥ ÀÖ¾î ¹ß»ö´ÜÀÇ ÀÛ¿ëÀ» µµ¿ÍÁÖ´Â ¿øÀÚ´Ü. 157. Áß¼º¹Ðµµ ÇÊÅÍ (neutral density filter) ƯÁ¤ÇÑ ÆÄÀ念¿ª ³»¿¡¼ °ÅÀÇ ÀÏÁ¤ÇÑ Åõ°úÀ²À» ³ªÅ¸³»´Â ÇÊÅÍ. 158. Áß¼º¼± (neutral line) µé¶á ¿øÀÚ°¡ ¹ß±¤ÇϵçÁö ¶Ç´Â ³·Àº ¿¡³ÊÁö ÁØÀ§¿¡ ÀÖ´Â ¿øÀÚ°¡ Èí¼öÇÏ¿© »ý±â´Â ¼±½ºÆåÆ®·³. 159. Áß¼ö¼Ò ¹æÀü°ü (deuterium lamp) Áø°ø Áß¿¡ ¾ÆÁÖ ³·Àº ¾Ð·ÂÀ¸·Î ºÀÀÔÇÑ Áß¼ö¼Ò Áß¿¡¼ÀÇ ¾ÆÅ©¹æÀüÀ» ÀÌ¿ëÇÏ´Â ¹æÀü°ü. Àڿܼ±ºÎÀÇ ¿¬¼Ó ½ºÆåÆ®·³ ±¤¿øÀ¸·Î¼ »ç¿ëµÈ´Ù. 160. Á÷·ù Çö󽺸¶ ¹ß±¤ºÐ±¤ºÐ¼® (direct current plasma atomic emission spectrochemical analysis) Á÷·ù Çö󽺸¶¸¦ ±¤¿øÀ¸·Î ÇÑ ¹ß±¤ºÐ±¤ ºÐ¼®. 161. û»ö À̵¿ (blud shift) ÃÖ´ë Èí¼öÆÄÀåÀÇ ´ÜÆÄÀåÀ¸·ÎÀÇ ÆÄÀå À̵¿. 162. ÃÊÀ½¼Ó Á¦Æ® ºÐ±¤¹ý (supersonic jet spectroscopy, SSJS) ¹Ì¼Ò ³ëÁñ·ÎºÎÅÍ Áø°ø°è ³»·Î ½Ã·á±âü¸¦ ºÐÃâ È®»ê½ÃÅ´À¸·Î½á ¾ò¾îÁö´Â ½Ã·á»ìÀ» »ç¿ëÇÏ´Â ºÐ±¤¹ý. ºÐÀÚ¸¦ ¼ø°£ÀûÀ¸·Î ±ØÀú¿ÂÀ¸·Î ±Þ·©½ÃÄÑ ºÐÇØ°¡ ÀߵǴ ½ºÆåÆ®·³ µîÀ» ¾ò´Â ¸ñÀûÀ¸·Î »ç¿ëµÈ´Ù. 163. ÃÖÀú µé¶ä Àü¾Ð (the lowest excitation voltage) °¢ ¿øÀÚ¿¡¼ ƯÁ¤µÈ °íÀ¯ X¼±À» µé¶ß°Ô Çϱâ À§ÇÏ¿© ÇÊ¿äÇÑ ÃÖÀúÇѵµÀÇ µé¶äÀü¾Ð. 164. ÄÚÆ° È¿°ú (Cotton effect) ¼±±¤ºÐ»ê ½ºÆåÆ®·³¿¡¼ ±¤ÇÐ È°¼º Èí¼ö¶ì ºÎ±Ù¿¡ Á¤À̳ª ¿ªÀÇ ÃÖ´ë °ªÀ» °®´Â °î¼±ÀÌ ³ªÅ¸³ª´Â °Í. 165. ÄÜÁîÀÇ ¿ìÀ§¼º (Connes' advantage) °£¼· ºÐ±¤¹ý¿¡¼´Â ·¹ÀÌÀú ÆÄÀåÀ» ±âÁØÀ¸·Î ÇÏ¿© °£¼·Æĸ¦ (ÀÎÅÍÆä·Î±×·¥)¸¦ °èÃàÇÏ´Â °ÍÀ¸·Î¼ , ½ºÆåÆ®·³ ÆļöÀÇ Á¤¹Ðµµ°¡ ³ô´Ù°í Çϴ Ư¡. 166. Å©¼¼³íµ¿ (xenon lamp) °í¾Ð(¾à6±â¾Ð)À¸·Î ºÀÀÔÇÑ Å©¼¼³í ±âü Áß¿¡¼ÀÇ ¾ÆÅ©¹æÀüÀ» ÀÌ¿ëÇÏ´Â ¹æÀü°ü, Àڿܼ± ¿µ¿ª¿¡¼ ±ÙÀû¿Ü¼± ¿µ¿ª±îÁö °ÇÑ ¿¬¼Ó ½ºÆåÆ®·³À» ³½´Ù. 167. Å°¶ö¼º (chirality) ºÐÀÚ±¸Á¶°¡ ¼Õ´ëĪÀ» °®´Â °Í. 168. ÅÖ½ºÅϵî (tungsten lamp) ÅÖ½ºÅÙ Çʶó¸àÆ®¸¦ »ç¿ëÇÑ 320nmÀÌ»óÀÇ ÀåÆÄÀå ¿µ¿ª¿¡¼ »ç¿ëµÇ´Â ±¤¿ø¿ë µî. 169. Åð»ö (color fading) ÈÇйÝÀÀ, ÈíÂø ,Èí¼ö µîÀÇ °á°ú·Î ¹ÝÀÀ ¹°ÁúÀÌ ³ªÅ¸³½ »öÀÌ ¿¯¾îÁö´Â °Í. 170. Åõ°ú ÆÛ¼¾Æ® (percent transmission) Åõ°úÀ²À» ¹éºÐÀ²·Î ³ªÅ¸³½ °Í. 171. Åõ°úÀ² (transmittance) ºûÀÌ ¹°ÁúÀ» Åõ°úÇÏ´Â ºñÀ²À» Åõ°ú ÈÄÀÇ ºû ¼¼±â I¿Í Åõ°ú ÀüÀÇ ºû¼¼±â·® l0t =(l / I0)ÀÇ ºñ·Î Ç¥½ÃÇÑ °Í. 172. Æļö (wavenumber) ´ÜÀ§ ±æÀÌ (1cm)³»¿¡ ÀÖ´Â ÆÄÀǼö. º¸ÅëÀº Áø°ø¿¡¼ÀÇ °ª. ¥ò¶Ç´Â ¥ô·Î ³ªÅ¸³½´Ù. 173. ÆÄÀå (wavelength) ÀüÀÚÆÄÀÇ Æĵ¿À¸·Î ÀÎÁ¢ÇÑ °°Àº À§»óÁ¡ °£ÀÇ °Å¸®. º¸Åë ¥ë·Î Ç¥½ÃÇÑ´Ù. 174. ÆÄÀå ±³Á¤ (wavelength calibration) ºÐ±¤ ±¤µµ°èÀÇ ÆÄÀå ´«±ÝÀÌ ¿Ã¹Ù¸¥Áö¸¦ ¾Ë°í ÀÖ´Â ÆÄÀåÀÇ º¹»ç¸¦ ³»´Â ±¤¿ø ¶Ç´Â Èí¼öÇÏ´Â ¹°ÁúÀ» »ç¿ëÇÏ¿© º¸Á¤ÇÏ´Â °Í. 175. ÆÄÀå ºÐ»ê (wavelength dispersion) °¢Á¾ ÆÄÀåÀÇ ¼ººÐÀ» Æ÷ÇÔÇÏ´Â ºûÀ» ÇÁ¸®ÁòÀ̳ª ȸÀý °ÝÀÚ µîÀ» »ç¿ëÇÏ¿© ºÐ±¤ÇÏ´Â °Í. 176. ÆÄÀå ºÐ»ê¹æ½Ä (wavelength dispersive method) X¼±À» ºÐ±¤°áÁ´ , ȸÀý °ÝÀÚ µîÀÇ ºÐ±¤¼ÒÀÚ¸¦ »ç¿ëÇÏ¿© ºÐ±¤ÇÏ´Â ¹æ½Ä. 177. ÆÄÀå À̵¿ (wavelength shift) Èí¼ö ¶Ç´Â ¹ß±¤ ½ºÆåÆ®·³ÀÇ ÃÖ´ë ÆÄÀåÀÌ À̵¿ÇÏ´Â °Í. Àû»ö À̵¿°ú û»ö À̵¿ÀÌ ÀÖ´Ù. 178. ÆÄÀå ÁÖ»ç (wavelength scanning) ½ºÆåÆ®·³ ÃøÁ¤À» À§ÇØ ÆÄÀå, Áøµ¿¼ö ¶Ç´Â Æļö¸¦ ¿¬¼ÓÀûÀ¸·Î º¯È½ÃÅ°´Â °Í. 179. ÆÞ½º ºÐÆ÷ Çؼ®¹ý(¹ß±¤ ºÐ±¤ ºÐ¼®ÀÇ) (pulse distribution analysis (in emission spectrochemical analysis)) ½ºÆÄÅ© ¹æÀü¿¡¼ ÆÞ½º¸¶´ÙÀÇ ½ºÆåÆ®·³ ¼¼±â¸¦ ÃøÁ¤ÇÏ°í ±× ºÐÆ÷¸¦ Çؼ®ÇÏ¿© º¸±â¸¦ µé¸é, ¿ëÇؼº ¾Ë·ç¹Ì´½°ú ºÒ¿ëÇؼº ¾Ë·ç¹Ì´½ÀÇ ÆǺ° µîÀÇ »óźм®À» ÇÏ´Â ¹ß±¤ºÐ±¤¹ý. 180. Æç°ÔÀÌÆ® À̵æ (Fellgette's advantage) °£¼· ºÐ±¤¹ý¿¡¼´Â ÃøÁ¤ ÆÄÀ念¿ªÀÇ ½ÅÈ£¸¦ µ¿½Ã¿¡ ÃøÁ¤Çϱâ À§ÇÏ¿© ÃøÁ¤½Ã°£¿¡ ºñÇØ SNºñ°¡ Çâ»óµÇ´Â °ÍÀ» ¸»ÇÑ´Ù. 181. Æí±¤ Çؼҹý (depolarization method) Æí±¤ µé¶ä¿¡ ÀÇÇÑ Çü±¤ÀÇ Æí±¤ÀÌ ºÐÀÚ ¿îµ¿¿¡ ÀÇÇØ ½Ã°£ÀÌ °æ°úµÊ¿¡ µû¶ó ÇؼҵǴ Á¤µµ¸¦ ÃøÁ¤ÇÏ´Â ¹æ¹ý. 182. Æò¸é ºÐ±¤¼ÒÀÚ(X¼±ÀÇ) (plane dispersive element (in X-ray analysis)) °áÁ¤ °ÝÀÚÀÇ ºê·¡±× ¹Ý»ç¸¦ ÀÌ¿ëÇÏ¿© X¼±À» ºÐ±¤Çϱâ À§ÇÑ ¸ð¾çÀÌ Æò¸éÀÎ ¼ÒÀÚ. 183. ÆòÇàÈ ÀåÄ¡ (collimator) Æò¸é ºÐ±¤¼ÒÀÚ¸¦ »ç¿ëÇÏ°í ÀÖÀ» ¶§¿¡ ÇÊ¿äÇÑ ÆòÇàºû»ìÀ» ¸¸µé±â À§ÇÑ ¼ÒÀÚ. 184. Ç¥¸éÁõ° ¶ó¸¸»ê¶õ (surface enhanced Raman scattering SERS) ·¹ÀÌÀú¤ý ¶ó¸¸ ºÐ±¤¿¡¼ ¿ÂÇ¥¸é µîÀ¸·Î Áú¼Ò ÈÇÕ¹° µîÀÌ ¶ó¸¸ ½ºÆåÆ®·³ÀÌ ÇöÀúÇÏ°Ô Áõ°µÇ´Â °Í. 185. Ç¥ÁØ Ã·°¡¹ý (standard addition method) °°Àº ¾çÀÇ ¸î °³ÀÇ ½Ã·á ¿ë¾×À» ºÐ¼® ´ë»ó ¿ø¼Ò°¡ °¢°¢ ´Ù¸¥ ³óµµ·Î ÇÔÀ¯µÇµµ·Ï Á¶Á¦ÇÑ °ÍÀ» »ç¿ëÇÏ¿© ³óµµ¿Í Áö½ÃÄ¡ÀÇ °ü°è¼±À» ÀÛ¼ºÇÏ°í ³óµµÃàÀÇ ÀÚ¸¥ Á¶°¢¿¡¼ ½Ã·á¿ë¾× ÁßÀÇ ºÐ¼® ´ë»ó ¿ø¼ÒÀÇ ³óµµ¸¦ ±¸ÇÏ´Â ¹æ¹ý. 186. Ç¥ÁØÈ ½Ã·á(¹ß±¤ ºÐ±¤ºÐ¼®ÀÇ) (sample for standardization) ÀÏÁ¤½Ã°£ ¶Ç´Â ÀÏÁ¤ ½Ã·á¸¶´Ù °Ë·®¼ºÀ» ±³Á¤Çϱâ À§ÇØ »ç¿ëÇÏ´Â ½Ã·á. 187. Çö¹Ì Çü±¤¹ý (microscopic fluorometry) Çö¹Ì°æ ½Ã¾ß¿¡¼ ÇÏ´Â Çü±¤ °üÂû ºÐ¼®¹æ¹ý. 188. Çü±¤ (fluorescence) ºÐÀÚ³ª ¿øÀÚ°¡ ºû¿¡ ÀÇÇØ ÁؾÈÁ¤ »óÅ·Πµé¶¹´Ù°¡ ¹Ù´Ú»óÅ·ΠõÀÌÇÒ ¶§¿¡ ¹ß»ýµÇ´Â ºû. 189. Çü±¤ ºÐ±¤ ºÐ¼®¹ý (fluorescence spectrometry) Çü±¤ ½ºÆåÆ®·³ ¶Ç´Â µé¶ä ½ºÆåÆ®·³À» ÃøÁ¤ÇÏ¿© ¹°ÁúÀ» Á¤¼º¤ýÁ¤·®ÇÏ´Â ¹æ¹ý. 190. Çü±¤ ½ºÆåÆ®·³ (fluorescence spectrum) ºÐÀÚ³ª ¿øÀÚ°¡ ƯÁ¤ÆÄÀÚÀÇ µé¶ä±¤(º¸Åë, ¼¼±â°¡ °¡Àå ¼¾ Çü±¤ÀÌ ¾ò¾îÁö´Â ÆÄÀÚÀÇ ºû)¿¡ Á¶»çµÇ¾î µé¶á ´ÙÀ½, ÁؾÈÁ¤ »óÅ·κÎÅÍ ¹Ù´Ú»óÅ·ΠõÀÌÇÒ ¶§ ¹æÃâµÇ´Â ÀüÀÚÆÄÀÇ ½ºÆåÆ®·³. 191. Çü±¤ Ç¥Áö¹ý (fluorescence labeling) ºÐ¼® ´ë»ó ¼ººÐÀÇ Çü±¤À» ÀÌ¿ëÇÏ¿© °ËÃâ °¨µµ¸¦ ³ôÀ̱â À§ÇØ ±× ¼ººÐ ºÐÀÚ¿¡ Çü±¤¼º ¹°ÁúÀ» °áÇÕ½ÃÅ°´Â °Í. 192. Çü±¤ X¼± (fluorescent X-ray) x¼±, r¼± µî¿¡ ÀÇÇØ µî¶á 2Â÷ x¼± Áß »ê¶õ x¼±ÀÌ ¾Æ´Ï°í ¹°Áú±¸¼º ¿øÀÚÀÇ ³»ºÎ ¿¡³ÊÁö¸¦ ¹Ý¿µÇÏ´Â X¼±. 193. Çü±¤ X¼± ºÐ¼®¹ý (fluorescent X-ray analysis) Çü±¤ X¼±À» ÃøÁ¤ÇÏ¿© ¹°ÁúÀ» Á¤¼º¤ýÁ¤·®ÇÏ´Â ¹æ¹ý. 194. ÈÇÐ ¹ß±¤¹ý (chemiluminescence method) ÈÇÐ ¹ÝÀÀ¿¡¼ ¹æÃâµÈ ¿¡³ÊÁö·Î µé¶á ÈÇÐ Á¾ÀÌ°¡ ³·Àº ¿¡³ÊÁö ÁØÀ§·Î õÀÌÇÒ ¶§ ¹æÃâµÇ´Â 2Â÷±¤À» ÀÌ¿ëÇÏ´Â ¹æ¹ý. 195. È®»ê ¹Ý»ç¹ý (diffused reflection method) ºÐ¸»À̳ª °ÅÄ£ ¸éÀ» °®´Â ½Ã·á¿¡ ºûÀ» Á¶»ç½ÃÄÑ ½Ã·á¸éÀ¸·ÎºÎÅÍ º¹»çµÈ ºû(È®»ê º¹»ç±¤)¿¡ ÀÇÇØ Èí¼ö ½ºÆåÆ®·³À» ¾ò´Â ¹æ¹ý. 196. ȯ¿ø ±âȹý (method for producing the atomic vapor by reduction) ½Ã·á ¿ë¾× Áß ºÐ¼® ´ë»ó ¼ººÐÀ» ȯ¿ø½ÃÄÑ ±âü »óÅ·Π¸¸µå´Â ¹æ¹ý. 197. ȯ¿ø ºÒ²É (reducing flame) °¡¿¬¼º ±âü°¡ °úÀ×À¸·Î Á¸ÀçÇÏ°í ȯ¿ø¼º ºÐÀ§±â°¡ µÇ¾î ÀÖ´Â ÈÇкҲÉ. 198. È帧 ¼¼Æ÷¹ý (flow cytometry) ±ØÈ÷ ÀÛÀº Áö¸§ÀÇ È帧»ì·Î È帣°í ÀÖ´Â À¯Ã¼ ÁßÀÇ ¼¼Æ÷ÀÔÀÚ¸¦ ·¹ÀÌÀú±¤ µîÀ¸·Î Á¶»çÇÏ¿© ÀÔÀÚ¿¡ ÀÇÇÑ ºûÀÇ »ê¶õ ¤ý Èí¼ö¤ý Çü±¤ µîÀ» ÃøÁ¤Çؼ ¼¼Æ÷¸¦ Á¤¼º¤ýÁ¤·®ÇÏ´Â ¹æ¹ý. 199. Èí±¤ Áõ°¡È¿°ú (hyperchromic effect) Èí¼ö ½ºÆåÆ®·³¿¡¼ ºÐÀÚ±¸Á¶ÀÇ º¯È µî¿¡ µû¶ó Èí¼ö¶ìÀÇ ¸ô Èí±¤°è ¼ö°¡ Áõ´ëÇÏ´Â °Í. 200. Èí±¤µµ (absorbance) ¹°ÁúÀÌ ±¤À» Èí¼öÇÏ´Â Á¤µµ As·Î¼ Åõ±¤µµ t ÀÇ ¿ª¼ö¿¡ ´ëÇÑ »ó¿ë´ë¼ö·Î Ç¥½ÃÇÑ °ª. As = log(1/t). 201. Èí¼ö (absorption) ÀüÀÚÆÄÀÇ ¹æ»ç°¡ ½Ã·á¹°ÁúÀ» Åë°úÇÒ ¶§, ½Ã·á¹°ÁúÀÌ ÀüÀÚÆÄÀÇ ÀϺΠ¶Ç´Â Àüü ÆÄÀå ¿µ¿ª¿¡ °ÉÃļ ±× ¼¼±â¸¦ °¨¼Ò½ÃÅ°´Â Çö»ó. 202. Èí¼ö °î¼± (absorption curve) Èí¼öÀÇ Å©±â¸¦ ¿¡³ÊÁö, ÆÄÀå µîÀÇ ÇÔ¼ö·Î¼ µµ½ÃÇÑ °Í. 203. Èí¼ö °î¼±ÀÇ ¾î±ú (shoulder of absorption curve) Èí¼ö °î¼± »ó¿¡¼ ÃÖ´ë ¶Ç´Â ÃÖ¼Ò¸¦ ³ªÅ¸³»Áö´Â ¾ÊÁö¸¸ ¼öÆò¿¡ °¡±î¿î ªÀº º¯°îºÎ. 204. Èí¼ö ½ºÆåÆ®·³ (absorption spectrum) ÀüÀÚÆÄÀÇ ¾î¶² ÆÄÀå ¹üÀ§ ¹æ»çÀÇ ÀϺΰ¡ ½Ã·á¹°Áú¿¡ µû¶ó Èí¼öµÇ¾î ¾ò¾îÁø ½ºÆåÆ®·³. 205. Èí¼ö ÃÖ´ë (absorption maximum) Èí¼ö¶ìÀÇ ÆÄÀ念¿ª ³»¿¡¼ ÃÖ´ëÀÇ Èí¼ö¸¦ ³ªÅ¸³»´Â ºÎºÐ. 206. Èí¼ö¶ì (absorption band) Èí¼ö ½ºÆåÆ®·³ Áß, ¾ó¸¶°£ ³Ð¾îÁø Èí¼ö¸¦ ³ªÅ¸³»´Â ÆÄÀå¶ì. 207. H-D °î¼± (H and D curve, Hurter and Driffield curve) »çÁø °¨±¤Á¦ÀÇ ±³Á¤°î¼±ÀÇ ÀÏÁ¾. °¨±¤Àç·á »ó¿¡ »ý±ä °¨±¤ºÎÀ§ÀÇ Èæȵµ¸¦ ³ëÃâ ´ë¼öÀÇ ÇÔ¼ö·Î¼ Ç¥½ÃÇÑ °Í. 208. K°è¿ X¼± (K-series X-ray) ¿øÀÚ¿¡ °íÀ¯ÇÑ X¼± Áß, ¿øÀÚ¿¡ ¼ÓÇÑ ÀüÀÚ°¡ K²®Áú¿¡ ÀÖ´Â ºó ±Ëµµ·Î õÀÌÇÔÀ¸·Î½á ¹ß»ýÇÏ´Â ÀϱºÀÇ X¼±. 209. L°è¿ X¼± (L-series X-ray) ¿øÀÚ¿¡ °íÀ¯ÇÑ X¼± Áß ¿øÀÚ¿¡ ¼ÓÇÏ´Â ÀüÀÚ°¡ L²®ÁúÀÇ ºó ±Ëµµ·Î õÀÌÇÔÀ¸·Î½á ¹ß»ýµÇ´Â ÀϱºÀÇ X¼±. |